TReX User Manual v15.30 Firmware
IO (2):
System voltage, current and internal operating temperature. RF is the temperature read directly
next to the RF power stage and will be higher than than the DIG board temperature while the
TReX is transmitting (not applicable for receiver only TReX units). Temperatures of the RF
power stage may reach 100 degrees Celsius under normal long term operation. These
temperatures are not the ambient temperature. The case of the TReX will NOT reach these
temperatures.
As with the previous IO screen, systems voltages and temperatures of all SLAVE TReX units
(up to 9 SLAVE units) can be viewed by pressing the down button if the TReX is configured to
be a MASTER.
IO (3):
This is the ALERT summary screen. This screen shows which alerting function is enabled and
active. There are many alerting functions possible such as link fail, RF fault, over temperature
and others. The screen shows through the bell icon in the top bar how many alerts have been
triggered since last cleared. The 3 digit count shows the total number of alerts raised for each
alert type. The large tick icon indicates that a particular alert is enabled. The bell icon for each
alert shows if there are new alerts that have been raised. See
Alert Handling
for details on
alert configuration.
© WTE Limited, 2022 – Christchurch New Zealand
Page 20 of 302