TReX User Manual v15.30 Firmware
DISABLED:
Setting to DISABLED ensures the maximum possible power savings even when an Ethernet
cable has been connected. When IP is DISABLED, current consumption will reduce by
approximately 150mA and disable the TCP stack.
HOST
This is the name that can be associated to the TReX. This name can be used directly instead
of the IP address to address the TReX. By default is “WTE-TReX”
LOCAL IP
IP Address for access to the TReX.
SERVER
IP Address for the TCP CLIENT to connect to. When performing a PING this is the resolved
address that is used.
MASK
IP Mask
GATE
IP Gateway
DNS1
Primary Domain Name Server
DNS2
Secondary Domain Name Server.
TCP PORT
The port to use for TCP client TCP server connections. Default is 5080.
PING SERVER
Selecting this item results in a PING being sent to the SERVER address. Reply expected will
be the responding IP address and status (OK/TIMEOUT/NOT RESOLVED).
This item is useful for testing connectivity. If the TReX cannot successfully PING the
SERVER, it is likely that a firewall network filtering rule is preventing the connection.
Note
: When changing IP configuration, new settings are not applied until leaving the MENU
or the unit is restarted.