TReX User Manual v15.30 Firmware
Output Config Sub-Menu
MODE
When set to IO the output can be controlled through TELEMETRY settings or through output
control messages that may be received. Setting to IO will show the output to be configured to
either IO or IO MSHOT depending on the MSHOT setting.
On start outputs are ALWAYS LOW. After the expiration of any MONOSHOT period for an
output, the OUTPUT will return to the LOW state.
When RIC RANGE X, then the output is configured to close, either LATCHED or MSHOT
when a message is received with a RIC within that RANGE. RIC RANGE N controls
OUTPUT N.
MONOSHOT
If LATCHED or RIC RANGE the output will remain in the set state until another message is
received to change the state. If set to a time, then after receiving a message to operate HIGH
the output will return to a LOW state after this period of time has passed.
ALERT
If ENABLED, the output is able to generate an ALERT when operated. See
Alert Handling
.
© WTE Limited, 2022 – Christchurch New Zealand
Page 97 of 302