TReX User Manual v15.30 Firmware
RX Menu
RIC RANGES
Specifies up to 8 RIC RX ranges for decoding. Messages received with RIC codes not allowed
with the RX_RANGE will be discarded by the receiver.
Note:
When configuring the RIC RANGE, the LOW RIC must not be higher than the HIGH
RIC and the HIGH RIC must not be lower than the LOW. Any attempt to configure illegally
will reset the RIC RANGE to ensure these rules are not broken. Any RIC RANGE with a
LOW RIC set to 0000000 will NOT be used.
LINK FAIL TIME
This is the number of seconds (up to 240) that is allowed to pass in-between received messages
without setting the LINK FAIL output (if LINK FAIL output is configured).
ALERT
Visual notification and repeating beep (at a configurable interval) when a message is received
that meets the conditions for raising an alert. See
ALERT FILTER
.
If the ALERT output is enabled the configured output will also operate.
Can be configured from 0-250 seconds. When set to 0 the alert is disabled.
© WTE Limited, 2022 – Christchurch New Zealand
Page 53 of 302
Summary of Contents for TReX-460
Page 87: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 87 of 302...
Page 286: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 286 of 302...
Page 302: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 302 of 302...