TReX User Manual v15.30 Firmware
DD = DAC2 maximum count. Default 1023.
EE = ADC1 minimum count. Default 0.
FF = ADC1 maximum count. Default 1023.
GG = ADC2 minimum count. Default 0.
HH = ADC2 maximum count. Default 1023.
Typical usage:
*TREX_AN_CAL=0,1023,0,1023,0,1023,0,1023,
*LIMITS
Sets parameters used to set max and minimum limits used to protect the TReX from
installation faults. This command is for factory use only. Linked to the MIN PWR, MAX
PWR and MAX I items found in MENU->SYSTEM->FACTORY.
*LIMITS=AA,BB,CC
where:
AA = minimum output power sense setting. If, during a transmission this output power
is not achieved, a low output fault condition will be raised. Default value 10.
BB = maximum output power sense setting. During a transmission, the output power is
not permitted to exceed this level. If it is reached, a fault condition will be
raised. Default value 1000.
CC = Current limit in mA. This is the maximum current permitted during transmission.
This limit ensures that the TReX and connected power supply is protected during an
installation fault condition. Default value 1500.
CC = Current limit in mA. This is the maximum current permitted during transmission.
This limit ensures that the TReX and connected power supply is protected during an
installation fault condition. Default value 1500.
*TIME_SRC
Sets the method by which the TReX maintains internal time.
*TIME_SOURCE=X
where:
X is the method of maintaining internal time
0 = NONE
1 = FLEX
2 = SEQ TEST
3 = RTC
© WTE Limited, 2022 – Christchurch New Zealand