TReX User Manual v15.30 Firmware
Receive Commands
*RX_ENABLE
Allows the receiver to be disabled to save power if required. Set to 0 to set to SIMPLEX. Use
1 for DUPLEX operation (may be set to different frequency than the transmitter), 2 for RX
DISABLED operation. Set to 3 for TX DISABLED operation.
Typical usage:
*RX_ENABLE=0<CR>
*RX_FREQ
Specifies the receive frequency in Hz (range limited to the variant of product).
Typical usage:
*RX_FREQ=160000000<CR>
*RX_BAUD
Specifies the baud rate of the receiver.
Accepts: 512_25, 512_12, 512_6, 1200_25, 1200_12, 1200_6, 1600_25, 2400_25, 2400_12,
2400_6, 4800_25, 4800_12, 4800-4L_6, 9600_25, 9600-4L_25, 9600-4L_12, 16K-4L_25,
16K-4L_12, 32K-4L_25
Typical usage:
*RX_BAUD=512_25<CR>
*RX_PROTO
Specifies the protocol to apply for serial output, accepts WTE, RAW and AUX. See protocol
section for more detail on protocols and configuration.
Typical usage:
*RX_PROTO=WTE<CR>