![WTE TReX-460 User Manual Download Page 108](http://html1.mh-extra.com/html/wte/trex-460/trex-460_user-manual_1000427108.webp)
TReX User Manual v15.30 Firmware
Transmit Commands
*TX_FREQ
Specifies the transmit frequency in Hz. For the TReX-460 the minimum is 421000000 and
maximum is 480000000.
Typical usage:
*TX_FREQ=460000000<CR>
*TX_PROTO
Specifies the protocol to apply for serial input. Accepts WTE, RAW and AUX.
Typical usage:
*TX_PROTO=WTE<CR>
Note: See protocol section for more details on protocols and configuration.
*TX_BAUD
Specifies the baud rate of the transmitter when using a protocol that does not permit a baud rate
to be specified.
Accepts: 512_25, 512_12, 512_6, 1200_25, 1200_12, 1200_6, 1600_25, 2400_25, 2400_12,
2400_6, 4800_25, 4800_12, 4800-4L_6, 9600_25, 9600-4L_25, 9600-4L_12, 16K-4L_25,
16K-4L_12, 32K-4L_25
Typical usage:
*TX_BAUD=512_25<CR>
Note: This product has been certified for use in multiple markets. The modulation 32K-4L_25
is compliant under FCC only – it is the responsibility of the user to ensure that this modulation
is used in the application territories only.
*TX_PWR
Specifies the output power of the transmitter. Also allows the high power load matching
method to be specified.
Syntax:
*TX_PWR=A,B<CR>
Where:
•
A is 250MW, 500MW, 1W, 2W, 4W
•
B (optional) is 0 if current sense is primarily used for power setting at 4W (default) or 1
if ADC power sense is primarily used. Default method is more tolerant to load
© WTE Limited, 2022 – Christchurch New Zealand
Page 108 of 302
Summary of Contents for TReX-460
Page 87: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 87 of 302...
Page 286: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 286 of 302...
Page 302: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 302 of 302...