Operating hours
Sum of the pump's active hours
of operation
(meter can be reset by infrared
interface)
4.2.2.0
Consumption
Energy consumption
in kWh/MWh
4.2.3.0
Countdown, pump
cycling
Time to pump cycling in h
(at a resolution of 0.1 h)
Shown only for DP-MA and
internal pump cycling Can be
set in the service menu
<5.1.3.0>
4.2.4.0
Remaining time
until pump kick
Time until the next pump kick
(after a pump has had a 24 h
standstill (e.g. via Ext. Off), it will
be automatically operated for
5 seconds)
4.2.5.0
Mains On counter
Number of switching-on proce-
dures of the supply voltage
(each occasion the supply
voltage is established after an
interruption is counted)
4.2.6.0
Pump kick counter
Number of pump kicks that have
occurred
4.3.0.0
States
4.3.1.0
Base-load pump
The value display statically
shows the identity of the regular
base-load pump.
The unit display statically shows
the identity of the temporary
regular base-load pump.
Only displayed in DP-MA
mode
4.3.2.0
SSM
ON
State of the SSM relay if there is
no fault signal
OFF
State of the SSM relay if no fault
signal is present
4.3.3.0
SBM
ON
State of the SBM relay if a readi-
ness/operation or mains On sig-
nal is present
OFF
State of the SBM relay if no read-
iness/operation or mains On sig-
nal is present