6. Operation and fault handling
Page 32
105466
– TW-31-E - V1.9 - 06.04.2021
6.2 Milk removal YES or NO
Examples for the use of the tank monitor.
ATTENTION:
Do not simply confirm the alarms of the tank monitor.
It is essential to investigate and remedy the cause of the alarm in order
to avoid harmful effects on the milk!!!!!!
Even without an alarm message, the operator of the equipment has to
ensure the transportability of the milk!!!!!
No alarm
–
Milk may be drawn off.
The driver goes to the TW-31 and checks the tank monitor.
If the green LED is on, milk may be drawn off.
Once the milk has been taken, the driver starts the cleaning process.
Informative alarm -
Milk may be drawn off.
The driver checks the LEDs at the tank monitor
The green LED is blinking
– alarm horn sounds - error code on display.
Milk can be removed -> farmer has to be informed.
The farmer investigates ((and remedies) the cause of the error and presses
the button “RESET” -> the alarm horn stops.
The farmer presses button “RESET” once again -> the green LED flashes
permanently.
(The informative alarm is confirmed and deleted by the push button).
Once the milk has been removed, the driver starts the cleaning process.
Remark:
If the informative alarm is not reset, the green LED and the error code will con-
tinue to blink on the display -> even after the next cleaning cycle.
* if parametrized
Green = on
Red = off
no alarm
Green = flashing
Red = off
Informative alarm
(Press RESET button)
after RESET
Green = on
Red = off
Informative alarm
WARNING