6. Operation and fault handling
105466
– TW-31-E - V1.9 - 06.04.2021
Page 33
to section 6.2: Milk removal YES or NO
Critical alarm -
Milk must not be taken out.
The driver checks the LEDs at the tank monitor.
The red LED is blinking or flashing, an error code is displayed and an alarm
horn sounds.
The driver informs the farmer -> together they investigate the cause of the
critical alarm. (The critical alarm codes are retrieved from the display and
identified by means of the error table. See section 6.5).
Farmer and driver determine together whether the milk can be fed into the
tank, despite the alarm.
With the RESET-button the farmer confirms the alarm ->
the alarm horn stops
– the red LED continuous to flash.
The farmer presses the RESET-button again ->
the red LED flashes permanently.
After emptying the tank the cleaning process has to be started.
Only when the cleaning cycle has been active for at least 10 minutes, the tank
monitor automatically resets all critical alarms.
Green = an
Red = flashing
critical alarm
(press RESET button)
after RESET
Green = off
Red = on
critical alarm