7. Setting of parameters
105466
– TW-31-E - V1.9 - 06.04.2021
Page 59
to section 7.9
Ebene “I / O test parameters” (o- parameters)
Test digital inputs
All inputs [o.21 to o.28] can be selected via the arrow keys and tested as
follows:
Select the desired parameters with the arrow keys.
Press the SET key briefly: '0' or '1' appears in the display (depending
on the current switching state of the respective component).
Change switch state (e.g., safety switch).
The display toggles between '0' and '1'.
Press the SET key again: The display shows the current parameter
name again.
Range
Def.
o.21 Test digital input DE1
0 .. 1
- - -
o.22 Test digital input DE2
0 .. 1
- - -
o.23 Test digital input DE3
0 .. 1
- - -
o.24 Test digital input DE4
0 .. 1
- - -
o.25 Test digital input DE5
0 .. 1
- - -
o.26 Test digital input DE6
0 .. 1
- - -
o.27 Test digital input DE7
0 .. 1
- - -
o.28 Test digital input DE8
0 .. 1
- - -
o.29 Test digital input DE9
0 .. 1
- - -
o.30 Test digital input DE10
0 .. 1
- - -
o.31 Test digital input DE11
0 .. 1
- - -
o.32 Test digital input DE12
0: input signal low
1: input signal high
0 .. 1
- - -
Test and setting level inputs
Range
Def.
o.41 Level 1
-10 .. 10
0
o.42 Level 2
-10 .. 10
0
-10: less sensitive
0: normal
10: more sensitive
Adjust sensitivity: Green LED "OK" lights up
if the respective o.41 / o.42 level is detected
Display agitator capacity
(Procedure as for testing the digital inputs)
o.71 Agitator 1
in watt
o.72 Agitator 2
in watt
Others
o.98 Software version supply board
Display of the software version of the power supply.
Uses for communication with the service technician.