6. Operation and fault handling
Page 34
105466
– TW-31-E - V1.9 - 06.04.2021
to section 6.2: Milk removal YES or NO
Cr informative alarm -
Milk must not be taken out.
Der The driver checks the LEDs at the tank monitor.
Green and red LEDs are blinking, an error is displayed and an alarm horn
sounds.
The driver informs the farmer -> together they investigate the cause of the
critical and informative alarms. (The alarm codes are retrieved from the
display and identified by means of the error table. See section 6.5).
Farmer and driver determine together whether the milk can be fed into the
tank, despite the alarm.
With the RESET-button the farmer confirms the critical alarm at first -> the
alarm horn stops.
The farmer presses the RESET-button again -> the red LED flashes
permanently.
Afterwards the farmer confirms the informative alarm -> the green LED turns
off.
After emptying the tank the cleaning process has to be started.
Only when the cleaning cycle has been active for at least 10 minutes, the tank
monitor resets automatically all critical alarms.
Green = flashing
Red = flashing
cr informative alarm
(press RESET button)
after RESET
Green = flashing
Red = on
cr informative alarm
(press RESET button)
after second RESET
Green = off
Red = on
cr informative alarm
OK
ALARM