7. Setting of parameters
Page 46
105466
– TW-31-E - V1.9 - 06.04.2021
to section 7.3:
Level “General tank monitor parameters” (h parameters)
Setting system times
Fault
Range
Def.
h31 Max. interruption of cooling
F31
0..999 min.
60
h32 Max. time without cooling after finishing of
cleaning
F32
0..5000
min
600
h33 Min. cleaning interval
F33
0 .. 250 h
78
Monitoring of detergent see section 8.10
Fault
Range
Def.
h35 Monitoring of detergent “alkaline” by float
switch
0 = deactivated
1 = wiring “high active”
2 = wiring “low active”
F35
0 .. 2
0
h36 Monitoring of detergent “acidic” by float
switch
0 = deactivated
1 = wiring “high active”
2 = wiring “low active”
F36
0 .. 2
0
Settings monitoring sensor
Fault
Range
Def.
h38 Max. temperature difference monitoring
sensor to control sensor cooling
For this function the monitoring sensor in param-
eter [A50] has to be activated.
F38
1,0 .. 5,0
2,0
Setting milk times to monitor „cooling activated”
Range
Def.
This function triggers an alarm if cooling has not been acti-
vated at the entered milk times. This is to prevent to forget the
activation of the cooling in case of the first milking after the
cleaning.
h41 milk time 1
F22
00:00..23:59
--:--
h42 milk time 2
F22
00:00..23:59
--:--
h43 milk time 3
F22
00:00..23:59
--:--
Additional information on the errors see section 6.5.2