7. Setting of parameters
Page 42
105466
– TW-31-E - V1.9 - 06.04.2021
7.2 Change and save parameter values
The TW-31 is configured in 7 different parameter levels.
To change parameters in one of the lower levels, enter the corresponding 'level
code'.
Enter the level code
Proceed as follows:
Press the "SET" button for 5 seconds:
The display shows '0000' - the first '0' flashes.
Use the arrow keys to set the first digit or letter of the desired code.
Confirm the correct digit with "SET".
The set digit has been accepted - the second '0' flashes.
Use arrow keys to set the second digit.
Set third and fourth digits as well:
The first parameter of the selected level now appears.
If an incorrect code is entered, the control switches back to the operation mode.
Working level
CODE
h = General tank monitor parameter
Code: 4711
H = Extended tank monitor parameter
Code: F94A
F = Alarm configuration
Code: FFFF
A = Hardware configuration
Code: A384
C = Sensor adjustment
Code: C212
E = Service parameter
Code: EA03
o. = I/O test parameter
Code: 10E5