to section 6.5: Listing fault memory and description
F53 Thermal protection compressor
The motor protection switch for the compressor contactor of the tank and
the ice water preparer is activated.
Function is activated in parameter [h11].
F56 Broken sensor
The control unit is not receiving any signals from the sensor.
Possible cause of fault:
- Temperature sensor faulty
- Sensor cable damaged
F57 Sensor short circuit
as F56, but fault code F57 is displayed.
F58 Sensor range exceeded
Sensor reports upward or downward exceeding of measuring range
as F56, but fault code F58 is displayed.
F59 Signal error mode detection
If the tank monitor receives different signals for the mode detection (trig-
ger signal for cooling and cleaning at the same time), error F59 is dis-
played.
6.5.4 System alarms external sensors
F60 Erroneous communication with agitator monitoring module
and phase error (only for ESVAW-003). See parameter [A85].
F61 Erroneous communication with email or sms modem
See parameter [A73].
F85 Phase error
Error is displayed when the power module ESVAW-003 (if available) de-
tects a phase error.
6.5.5 Test alarm
F99 Test alarm