Specialized Concentrated Focused
Machining Operations
「
33
」
4. Machining Operations
4.1. System Startup
The system interface is as shown in Fig. 4-1 after power on.
B o o t i n g t h e s y s t e m . . .
Fig. 4-1 System start-up interface
After the system is started,
―Back to REF. Point‖ will be prompted, as shown in Fig. 4-2. Press [ESC] to
cancel this operation. You need to adjust the following related parameters sequentially: port polarity (see
Chapter 4.5), pulse equivalent (see Chapter 4.3), axis output direction (see Chapter 4.2) and machine
stroke (see Chapter 4.4) before homing all the axes.
B ack to R E F .
P o in t?
O K
E S C
Fig. 4-2 Prompt to home all the axes after system started
4.2. Axis Direction Adjustment
Firstly confirm the positive direction of each axis according to the coordinate system adhering to the
right-hand rule before starting machine debugging.
After fixing the positive direction of each axis following the right-hand rule, manually operate the machine
to check if the axes move correctly. If the direction is opposite, modify the parameter
―Axis OutpDir‖.
Take X-axis as an example, manually move the X-axis, only to find it moves oppositely. To solve this
problem, you just need to change the value of X axis in the parameter
―Axis OutpDir‖ from ―Positive
(Negative)
‖ to ―Negative (Positive)‖.
Press the
―Menu‖ key
→
5. Mfr Param
→
2. Axis OutpDir, and then press the [OK] key to enter the
interface as shown below.