Installation, Connection and Energization
The power arm insertion must be performed with the help of the transport trolley as shown in
Figure 6.5 on page
6-6
and according to the following procedure.
1. Rotate the crank handle until the trolley reaches the floor level.
2. Remove the cell from the package and place it on the cart tray.
3. Move the cart close to the panel, lift the cell up to the necessary height and couple the cart tray to the panel
support,
Figure 6.6 on page 6-8
- pictures 2, 3 and 4.
4. Lock the cart wheels.
5. Push the cell, observing the alignment with the panel support, until the handles touch the panel support,
(
Figure 6.6 on page 6-8
- picture 5).
6. Push the two brackets of the insertion mechanism simultaneously until the locking system is activated,
(
Figure 6.6 on page 6-8
- pictures 6 and 7).
7. Lift the cart tray until it uncouple from the cell support and move the cart away from the panel
(
Figure 6.6 on page 6-8
- picture 8).