![WEG MVW3000 A0040 V023 User Manual Download Page 36](http://html1.mh-extra.com/html/weg/mvw3000-a0040-v023/mvw3000-a0040-v023_user-manual_950681036.webp)
4-8 | MVW3000
4
Technical Data
Ground loop
Shield
cables
Motor
PE
PE
PE
Inverter
L
(a)
Filter type 1, for applications with cable length between 200 and 500 m.
Shield
cables
Motor
Inverter
PE
PE
PE
Ground loop
C C C
L
L
L
(b)
Filter type 2, for applications with cable length above 500 m and retrofitting.
Figure 4.8 (a) and (b):
Output filters for MVW3000 inverters