5.5
Specification overview
5.5.1
Performance
5.5.1.1 Maximum speed and flow rate
The flowrate of the pump is based upon a combination of the drive model, control model and the pumphead
which may be fitted to the drive.
The maximum speed and flow rate is provided in the table below.
Model: (Manual, PROFIBUS, Universal,
Un)
Model: Remote
Speed
Flow rate
Flow rate
Drive
Pump head
RPM
ml/min
US
GPH
RPM ml/min US
GPH
qdos 20
ReNu 20 SEBS
ReNu 20 PU
CWT 30 EPDM
55
55
125
333
460
500
5.30
7.29
7.93
55
55
û
333
460
û
5.30
7.29
û
qdos 30
ReNu 30 Santoprene
ReNu 30 SEBS
125
125
500
500
7.93
7.93
125
125
500
500
7.93
7.93
qdos 60
ReNu 60 Santoprene
ReNu 60 SEBS
ReNu 60 PU
125
125
125
1000
1000
1000
15.85
15.85
15.85
125
125
125
1000
1000
1000
15.85
15.85
15.85
qdos 120
ReNu 120 Santoprene
ReNu 60 Santoprene
ReNu 60 SEBS
ReNu 60 PU
140
125
125
125
2000
1000
1000
1000
31.70
15.85
15.85
15.85
140
û
û
û
2000
û
û
û
31.70
û
û
û
qdos CWT
CWT 30 EPDM
ReNu 20 SEBS
ReNu 20 PU
125
55
55
500
333
460
7.93
5.28
7.29
125
û
û
500
û
û
7.93
û
û
NOTE8
Flowrates are based on pumping water at 20 °C. The flowrate can vary with
inlet
and
discharge
pressure, see
"20.1 Performance" on page 212
for more information.
5 PRODUCT OVERVIEW
33