12.4.3 Step 3: follow the procedure for the connector type
The installation procedure differs depending upon the connection type, follow the procedure for that specific
connection type in sections below. Where there are any differences due to model type this is explained in the
procedure
12.4.3.1 Fitting hose barb connectors
Procedure
1. Ensure the pump is electrically isolated
2. Detach desired hose barb from hydraulic connector pack.
3. Place connection collar over hose barb and place on top of the pumphead seal
4. Place and tighten the connection collars by hand onto pumphead.
Procedure
5. Press tube onto hose barb until it reaches back face of hose barb.
6. Secure with suitable retaining clip.
7. Repeat procedure for other hose barb.
8. Check for leaks and tighten connection collar further if necessary.
12 INSTALLATION: PART 3 (FLUID PATH)
79