On a surface :
1. Install the pump on a surface which does not exceed a slope of 20° from horizontal
NOTICE
An excessive mounting slope can cause poor lubrication, resulting in damage to the pump though
accelerated wear. Install the pump on a surface which does not exceed a slope of 20° from
horizontal
2. With a surface mounting (such a plinth) suitable to :
l
Ensure that the fluid path
inlet
connections has adequate space to be installed and removed.
l
Ensure the pump is at a comfortable height for operation
3. Rated to support full weight of complete assembly and pumped product
4. Free of vibration
NOTICE
Excessive vibration can cause poor lubrication, resulting in damage to the pump though
accelerated wear. Install the pump on a surface free from excessive vibration.
5. Chemically compatible with the fluids being pumped
10 INSTALLATION: PART 1 (PHYSICAL)