11.3.2 Overcurrent protection
The power cable is fitted with a 20 A fuse. This fuse is a safety device, it must not be
l
bypassed
l
omitted
l
changed for a different current rating
11.3.3 Electrical isolation
The product does not come with an external supply isolation device.
Fit a suitable electrical supply isolation device, which is easily accessible during use, maintenance, or in the event
of an accident or emergency.
11.3.4 Power Cable (wiring)
11.3.4.1 Power cable specification
The power cable is non-detachable or user replaceable. If the cable becomes damaged contact your Watson-
Marlow representative to discuss the repair of the pump at a Watson-Marlow service centre.
!
WARNING
The blade fuse it not IP66 rated. An IP66 blade fuse must be installed in place of the supplied
blade fuse, where an IP66 rating is required.
Country
Cable specification
12-24 V plug (Part
numbers ending
in V)
2000 mm length. 2 core, red, black. UL CSA AWM I/II A/B Style 2587. 2 off 269G1 contact in
housing. Fitted with 20 A 32V fuse in IP31 blade fuse holder. M8 ring terminals (pre-fitted to
cable)
11 INSTALLATION: PART 2 (ELECTRICAL POWER)