17.6 Pipelines
Use seamless precision steel pipes in accordance with DIN 2391 and removable
pipe connections.
Pressure in the suction nozzle
The permitted pressure values at the suction nozzle of the pump must be maintained
(chapter 5.2).
Fig.
17.6: Configuration of the pump suction piping
Configure the suction piping cross-section as follows:
• Flow speed 1 m/s (in suction mode) (cavitation!)
• • Flow speed 1.5 m/s (inlet with slight overpressure)
Note the permitted input pressures in chapter 5.2.
min. 50 mm
Suction piping
Internal gear pumps
Pump combinations - configuration