7.3 Transport
This section describes how to transport internal gear pumps (weighing more than 20
kg) with a crane. Transport the pumps in the packaging as far as the installation site
(e.g. fork-lift truck, pallet jack, etc.)
Do not use loops to lift and transport the pumps!
Lift the internal gear pump as follows:
1.
Fit the steel ring screws (DIN 580) with plastic shims.
2.
Screw the steel ring screws into the internal thread of the pressure flange.
The plastic shims prevent damage to the sealing surface of the pressure flange.
Fig. 7.2: Steel ring screwed in
Fig. 7.1: Steel ring screw with plastic shim
Internal gear pumps
Packaging, transport