- 13 -
C1453
01000.
fm
English
Technical information
GB
D700/750 E2-E3
Dry shipping weight of engine
Kg
190
215
215
Maximum permanent lengthwise inclination
(with handwheel up)
Degrees
30°
30°
30°
Maximum permanent lengthwise inclination
(with handwheel down)
Degrees
35°
35°
35°
Maximum permanent crosswise inclination
Degrees
30°
30°
30°
POWER AND TORQUE
Maximum operating speed
rpm
2600
2600
2600
Maximum power
kW (CV)
rpm
36 (49)
41,2 (56)
48,6 (66,1)
Maximum torque
Nm (kgm)
rpm
145 (14,7) a 1600
195 (19,9) a 1400
260 (26,5) a 1200
CONSUMPTION AT MAXIMUM POWER
Specific fuel consumption
g/kWh
Specific oil consumption
g/CVh
0,5 - 1
0,5 - 1
0,5 - 1
FUEL SUPPLY CIRCUIT
Type of injection
Direct injection
Type of fuel
The engine has been designed to be powered by standard fuels available on the
European market (according to specifications DIN EN 590). If it is to be powered
by BIODIESEL fuels (according to specifications UNI EN 14214), it can be
mixed, up to 5%, with fuel available on the European market (according to regu-
lation DIN EN 590).
Important
Do not use fuels with specifications other than those indicated.
Fuel supply
Diaphragm pump
Injector supply
1 immersed injection pump per cylinder
LUBRICATION CIRCUIT
Type of lubrication
Forced lubrication
Circuit fuel supply
Rotor pump
Oil change including filter
(standard sump)
liters (kg)
Oil quantity at minimum level
(standard sump)
liters (kg)
Oil quantity at maximum level
liters (kg)
5÷7
5÷7
5÷7
The oil quantity at maximum level ( 5÷7 litre) depends on the capacity of the oil
sump with which the engine is equipped.
Oil pressure at minimum speed
(with started engine)
bar
1,2 - 1,6
1,2 - 1,6
1,2 - 1,6
Alarm for oil pressure too low
bar
0,4
0,4
0,4
Oil cooling
Oil/water cooler
COOLING CIRCUIT
Total capacity of the cooling circuit
(excluding radiator and relevant pipes)
litri
3,7
3,7
3,7
setting pressure of the expansion tank plug
bar
1
1
1
Coolant
Demineralised cold water 50% + Antioxidant and anti-freeze fluid 50%
(Inhibited glycol ethylene in compliance with ASTM D 3306)
Coolant maximum temperature alarm
°C
107
107
107
Opening value (start/finish) of thermostatic
valve
°C
80 (+/-2) / 95
80 (+/-2) / 95
80 (+/-2) / 95
Model
D703 E3
D703 TE3
D703 IE3