Manual VIPA System 200V
Chapter 1 Basics
HB97E - CP - Rev. 11/30
1-5
General description System 200V
•
Mounting rail 35mm
•
Peripheral modules with recessed labelling
•
Dimensions of the basic enclosure:
1tier width: (HxWxD) in mm: 76x25.4x74 in inches: 3x1x3
2tier width: (HxWxD) in mm: 76x50.8x74 in inches: 3x2x3
Please note that you can only install header modules, like the CPU, the PC
and couplers into plug-in location 1 or 1 and 2 (for double width modules).
1
2
4
3
D
V
I
M
E
M
O
R
Y
K
B
D
NET
X 2
3 4
VIPA 288-2BL10
PC 288
C
O
M
1
ON
PW
RN
BA
OFF
M
O
U
S
E
D
C
24
V
+
-
PW
ER
RD
BA
IM 253 CAN
ADR.
X 5
6 7
VIPA 253-1CA00
DC24V
+
-
1
2
0 1
DI 8xDC24V
SM 221
.0
.1
.2
.3
.4
.5
.6
.7
VIPA 221-1BF00
X 2
3 4
1
2
3
4
5
6
7
8
9
I0
DI 8xDC24V
SM 221
.0
.1
.2
.3
.4
.5
.6
.7
VIPA 221-1BF00
X 2
3 4
1
2
3
4
5
6
7
8
9
I0
DI 8xDC24V
SM 221
.0
.1
.2
.3
.4
.5
.6
.7
VIPA 221-1BF00
X 2
3 4
1
2
3
4
5
6
7
8
9
I0
DI 8xDC24V
SM 221
.0
.1
.2
.3
.4
.5
.6
.7
VIPA 221-1BF00
X 2
3 4
1
2
3
4
5
6
7
8
9
I0
DI 8xDC24V
SM 221
.0
.1
.2
.3
.4
.5
.6
.7
VIPA 221-1BF00
X 2
3 4
1
2
3
4
5
6
7
8
9
I0
DI 8xDC24V
SM 221
.0
.1
.2
.3
.4
.5
.6
.7
VIPA 221-1BF00
X 2
3 4
1
2
3
4
5
6
7
8
9
I0
DI 8xDC24V
SM 221
.0
.1
.2
.3
.4
.5
.6
.7
VIPA 221-1BF00
X 2
3 4
1
2
3
4
5
6
7
8
9
I0
DI 8xDC24V
SM 221
.0
.1
.2
.3
.4
.5
.6
.7
VIPA 221-1BF00
X 2
3 4
1
2
3
4
5
6
7
8
9
I0
Clack
•
Wiring by means of spring pressure connections (CageClamps) at the
front-facing connector, core cross-section 0.08...2.5mm
2
or 1.5 mm
2
(18pole plug)
•
Complete isolation of the wiring when modules are exchanged
•
Every module is isolated from the backplane bus
•
ESD/Burst acc. IEC 61000-4-2 / IEC 61000-4-4 (to level 3)
•
Shock resistance acc. IEC 60068-2-6 / IEC 60068-2-27 (1G/12G)
•
Class of protection IP20
•
Operating temperature: 0 ... +60°C
•
Storage temperature: -25 ... +70°C
•
Relative humidity: 5 ... 95% without condensation
•
Ventilation by means of a fan is not required
Structure/
dimensions
Installation
Reliability
Environmental
conditions
[1]
Header modules, like
PC, CPU, bus coup-
lers (double width)
[2] Header
module
(single width)
[3] Peripheral
module
[4] Guide
rails
Note
A maximum of 32 modules can
be connected at the back
plane bus. Take attention that
here the
maximum sum cur-
rent
of
3.5A
is not exeeded.
Please install modules with a
high current consumption
directly beside the header
module.
Summary of Contents for CP 240 RS232
Page 1: ...Manual VIPA System 200V CP Order No VIPA HB97E_CP Rev 11 30...
Page 2: ...L...
Page 14: ...Chapter 1 Basics Manual VIPA System 200V 1 6 HB97E CP Rev 11 30...
Page 126: ...Chapter 5 CP 240 EnOcean Manual VIPA System 200V 5 32 HB97E CP Rev 11 30...
Page 144: ...Chapter 6 CP 240 M Bus Manual VIPA System 200V 6 18 HB97E CP Rev 11 30...
Page 148: ...Index Manual VIPA System 200V A 4 HB97E CP Rev 11 30 M Stich...