Chapter 3 Project engineering
Manual VIPA System 200V
3-10
HB97E - CP - Rev. 11/30
The block must be called within the cyclic program section. This function is
used to acknowledge the start-up ID of the CP 240 and thus the synchro-
nization between CPU and CP. Furthermore it allows to set back the CP in
case of a communication interruption to enable a synchronous start-up.
Note!
A communication with SEND and RECEIVE blocks is only possible when
the parameter ANL of the SYNCHRON block has been set in the start-up
OB before.
Declaration
Name
Type
Comment
in ADR
INT
Logical
Address
in
TIMER_NR
WORD
No of timer for idle time
in_out ANL
BOOL
restart
progressed
in_out NULL
BOOL
internal
use
in_out
RESET
BOOL
1 = Reset the CP
in_out STEUERB_S
BYTE
internal
use
in_out STEUERB_R
BYTE
internal
use
Periphery address with which you may call the CP 240. Via the hardware
configuration you may set the periphery address.
Number of the timer for the delay time.
With ANL = 1 the handling block is informed that a STOP/START res.
NETZ-AUS/NETZ-EIN has been executed at the CPU and now a
synchronization is required. After the synchronization, ANL is automatically
set back.
Parameter is used internally.
RESET = 1 allows you to set back the CP out of your user application.
Here you have to set the bit memory byte where the control bits
ENDE_KOM, LETZTER_BLOCK, SENDEN_LAEUFT and FEHLER_KOM
for the SEND-FC are stored.
Here you have to set the bit memory byte where the control bits
LETZTER_BLOCK, EMPF_LAEUFT and FEHLER_EMPF for the
RECEIVE-FC are stored.
SYNCHRON_
RESET
Synchronization and
reset (FC 9)
ADR
TIMER_NR
ANL
NULL
RESET
STEUERB_S
STEUERB_R
Summary of Contents for CP 240 RS232
Page 1: ...Manual VIPA System 200V CP Order No VIPA HB97E_CP Rev 11 30...
Page 2: ...L...
Page 14: ...Chapter 1 Basics Manual VIPA System 200V 1 6 HB97E CP Rev 11 30...
Page 126: ...Chapter 5 CP 240 EnOcean Manual VIPA System 200V 5 32 HB97E CP Rev 11 30...
Page 144: ...Chapter 6 CP 240 M Bus Manual VIPA System 200V 6 18 HB97E CP Rev 11 30...
Page 148: ...Index Manual VIPA System 200V A 4 HB97E CP Rev 11 30 M Stich...