Manual VIPA System 200V
Chapter 3 Project engineering
HB97E - CP - Rev. 11/30
3-13
Periphery address with which you may call the CP 240. Via the hardware
configuration you may set the periphery address.
Number of the source data block of the remote station.
1. data word of the data block of the remote station.
Length of the data to send in words.
Number of the target block of the own station.
1. data word of the data block of the own station.
Coordination flag
The coordination flag serves to coordinate the receipt of data. The
coordination flag is set by the FETCH order. As long as the flag is set, no
other FETCH order may be released. If you want to prevent that data are
overwritten after receipt by new data, the deployment of the coordination
flag may be useful.
With FFFFh the coordination flag is deactivated.
Indicator word
Information concerning the order commissioning may be accessed by the
indicator word. More may be found at "RK512 communication - Indicator
word ANZW".
At proper function, all bits of this bit memory byte are "0". At errors an error
code is entered. The error setting is self-acknowledging, i.e. after
elimination of the error cause, the byte is set back to "0" again. The
following errors may occur:
1 = Data block not present
2 = Data block too short
3 = Data block number outside valid range
These parameters are internally used. They serve the information
exchange between the handling blocks.
ADR
QDB
QBDW
LANG
ZDB
ZBDW
KOOR
ANZW
PAFE
ANZ, GESE,
KOPF_GESE,
WART_DATEN,
EMPF_LAEUFT,
LETZTER_BLOCK,
FEHL_KOM
Summary of Contents for CP 240 RS232
Page 1: ...Manual VIPA System 200V CP Order No VIPA HB97E_CP Rev 11 30...
Page 2: ...L...
Page 14: ...Chapter 1 Basics Manual VIPA System 200V 1 6 HB97E CP Rev 11 30...
Page 126: ...Chapter 5 CP 240 EnOcean Manual VIPA System 200V 5 32 HB97E CP Rev 11 30...
Page 144: ...Chapter 6 CP 240 M Bus Manual VIPA System 200V 6 18 HB97E CP Rev 11 30...
Page 148: ...Index Manual VIPA System 200V A 4 HB97E CP Rev 11 30 M Stich...