XX002 Rev 799 Surveyor99 Dome System
Wiring
••••
37
WARNING: Connectors TB3 and J3 contain the same control signals. Therefore, wire the control cable to
TB3 OR J3, not both, to avoid communication errors.
WARNING: If Vicoax mode is being used, DO NOT wire TB3 or J3 for control, as this will cause the
Camera Dome Program to lock up upon power-up.
CONNECTOR/PIN
NUMBER
CONNECTOR TYPE
CONNECTOR/PIN LABEL
SIGNAL NAME
BNC (female)
VIDEO (J1)
J1
VIDEO
Video output
TERMINAL BLOCK
POWER (TB1)
TB1-1
H
Hot
TB1-2
N
Neutral
TB1-3
No connection
RJ-45
ALARM (J2)
J2-1
ALARM1
Alarm input 1
J2-2
VSSA
Ground
J2-3
ALARM2
Alarm input 2
J2-4
VSSA
Ground
J2-5
ALARM3
Alarm input 3
J2-6
VSSA
Ground
J2-7
ALARM4
Alarm input 4
J2-8
VSSA
Ground
TERMINAL BLOCK
COMM (TB3)
TB3-1
VSSA
Ground
TB3-2
RO+
Response out +
TB3-3
CI-
Command in -
TB3-4
RO-
Response out -
TB3-5
CI+
Command in +
RJ-45
COMM/RELAY (J3)
J3-1
CI+
Command in +
J3-2
RELAY NC
Relay, normally closed
J3-3
VSSA
Ground
J3-4
RO-
Response out -
J3-5
CI-
Command in -
J3-6
RELAY C
Relay, common
J3-7
RELAY NO
Relay, normally open
J3-8
RO+
Response out +
Table 1
Communication/Power Supply Board Connector Definitions
Summary of Contents for Surveyor 99
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ......
Page 38: ...28 Installation XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 48: ...38 Wiring XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 52: ...42 Configuration XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 54: ...44 Disassembling the Surveyor99 XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 58: ...48 Operation XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 60: ...50 Maintenance XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 62: ...52 Shipping Instructions XX002 Rev 799 Surveyor99 Dome System NOTES...