XX002 Rev 799 Surveyor99 Dome System
Installation
••••
23
b) Strip approximately 1 inch (25 mm) of insulation off all wires to be terminated in Terminal Blocks TB1
and TB3. Then strip approximately 0.25 inches (6 mm) of insulation off of each individual wire.
c) Make all connections to Terminal Blocks TB1 and TB3 with reference to Table 1. On TB3, the
COMMAND IN + (CI+) and COMMAND IN - (CI-) connections must be used for Simplex operation.
For Half Duplex operation, the additional signals RESPONSE OUT + (RO+) and RESPONSE OUT -
(RO-) must also be used. Insert each wire into its Terminal Block location and tighten the screw.
d) Terminate the video (coaxial) cable with a BNC type male connector.
e) Terminate the 8-conductor alarm cable or communication/relay cable with an RJ-45 male connector, if
connectors J2 or J3 will be used.
WARNING: If Vicoax mode is being used, DO NOT wire TB3 or J3 with control signals, as this will cause
the Camera Dome Program to lock up upon power-up.
9. Reinstall the Terminal Blocks TB1 and TB3 into the Communication Power Supply Board at the proper
block frames.
10. Install the Video BNC cable connector to the Communication/Power Supply Board’s mating BNC
Connector at location J1.
11. Plug in all RJ-45 cable connectors to their corresponding mating connectors J2 and J3.
WARNING: Failure to insert the RJ-45 Connectors into the correct mating connectors can cause damage
to the Communication Power Supply Board upon power-up.
12. Route all cables under the Cable Clamp as shown in Figure 21a.
13. Configure the Surveyor99 communication and address DIP Switches as follows:
a) If RS-422 Mode will be used:
1. Set switches 1 - 8 on DIP Switch 1 (S1) to Surveyor99’s address as specified in Table 2. All
addresses between 0 and 255 are valid (address 0 is the same as camera number 256).
2. Set switch 1 on DIP Switch 2 (S2) to the appropriate video mode (PAL/OFF or NTSC/ON).
3. Set switch 2 on DIP Switch 2 (S2) to the OFF position (VPS/NOVA mode).
4. Set switch 3 on DIP Switch 2 (S2) to the OFF position (SIMPLEX/DUPLEX).
5. Set switch 4 on DIP Switch 2 (S2) to the appropriate communication protocol (RS-422 or RS-485).
b) If Vicoax Mode will be used:
1. Set switch 1 on DIP Switch 2 (S2) to the appropriate video mode (PAL or NTSC).
Summary of Contents for Surveyor 99
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ......
Page 38: ...28 Installation XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 48: ...38 Wiring XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 52: ...42 Configuration XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 54: ...44 Disassembling the Surveyor99 XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 58: ...48 Operation XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 60: ...50 Maintenance XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 62: ...52 Shipping Instructions XX002 Rev 799 Surveyor99 Dome System NOTES...