30
••••
Wiring
XX002 Rev 799 Surveyor99 Dome System
Typical Relay and Alarm Connections
Alarm Input and Relay Output type signals are also carried on individually-shielded twisted-pair cable sets. The
signals are defined in the following descriptions.
Alarms 1-4 are electronic TTL (transistor-transistor
logic) type inputs that are driven by a dry contact
type switch. These signals are connected to RJ-45
Connector J2. Each input has two states, open and
closed. For example, in Figure 26, a door switch
can activate an alarm when connected to a
Surveyor99 Alarm Input. As a guideline (under
normal conditions), the cable should be 22 AWG for
a 1000 foot (305 m) distance The states
correspond to defined TTL designations as follows:
OPEN = HIGH and CLOSED = LOW
where: HIGH = 5 VDC and LOW = < 1 VDC
Since dry contact switches are normally defined in
terms of their inactive or “normal” state, the
following holds true:
NORMALLY CLOSED (NC) = ACTIVE HIGH
(OPEN)
NORMALLY OPEN (NO) = ACTIVE LOW
(CLOSED)
The “active” state can be programmed through the
Surveyor99 menu system. These signals are
connected to RJ-45 Connector J3. Alarm signals
can be programmed for their status
(enabled/disabled), active level definition (high/low),
action/reset function (none, preset, aux on, aux off
or tour), acknowledgement mode
(automatic/manual) and report status (yes/no).
The Relay Output is an actual Relay Output dry
contact which directly drives external devices. For
example, a light can be turned on and off when the
Relay Output is connected to the light circuit. Refer
to Figure 27. The Relay Output contact can be
programmed for its active level definition (high/low),
power-on state definition (on/off) and output type
definition (momentary or latching).
The Relay Output can handle a signal of about 35
volts at 1 A typical. There is one Relay Output
contact located on the J3, RJ-45 Connector.
Connect the circuit to be switched to the connector
pins labeled RELAY C and RELAY NC or RELAY
NO for a normally closed or normally open
connection, respectively.
Figure 26
Typical Alarm Circuit
Figure 27
Typical Relay Circuit
Summary of Contents for Surveyor 99
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ......
Page 38: ...28 Installation XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 48: ...38 Wiring XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 52: ...42 Configuration XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 54: ...44 Disassembling the Surveyor99 XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 58: ...48 Operation XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 60: ...50 Maintenance XX002 Rev 799 Surveyor99 Dome System NOTES...
Page 62: ...52 Shipping Instructions XX002 Rev 799 Surveyor99 Dome System NOTES...