background image

AXIS 240Q Blade - Rack Solution Installation 

Guide

Summary of Contents for 240Q Blade

Page 1: ...AXIS 240Q Blade Rack Solution Installation Guide ...

Page 2: ...eiver in a domestic environment it may cause radio interference Install and use the equipment according to the instruction manual Australia This electronic device meets the requirements of the Radio communications Electromagnetic Compatibility Standard 1998 AS NZS 3548 Compliance is not valid for unshielded network cables Liability Every care has been taken in the preparation of this manual Please...

Page 3: ...r s Manual for information on using the control button Indicators Qty Item Title Variants 1 Video server AXIS 240Q Blade Video Server 2 Connector 14 pin terminal connector block 1 Warranty Document 1 Installation Guide AXIS 240Q Installation Guide 1 CD Documentation and software 1 This Document AXIS 240Q Blade Rack Solution Installation Guide Network Amber Flashes for activity on a 10 Mbit s netwo...

Page 4: ...408C1A2B3C 00 40 8C 1A 2B 3C P N part number is the product model number Bus Connector Physical interface to the I O Block Connector on the rack DIP Switches Each video input has a corresponding line termination DIP switch The AXIS 240Q is supplied with the line termination enabled for each video input that is with the DIP switches set to ON down position If the video signal is to be connected in ...

Page 5: ...tor Axis Blade video servers are designed for 10 Mbps Ethernet and 100 Mbps Fast Ethernet networks and connect via a standard RJ 45 connector DC Power 12VDC Power output This connector can drive the photo coupler inputs or other equipment such as an IR sensor A maximum current for all pins of 1000mA can be sourced from the DC output Power Connector Input power 100 240 VAC 50 60 Hz 1 6A I O Termina...

Page 6: ...ption 1 RS 232 RI 15 RS 485 A non inverting A half duplex RS 485 interface for con trolling auxiliary equipment e g PTZ devices 2 RS 232 CTS 16 RS 485 B inverting 3 RS 232 RTS 17 Transistor Output 4 With a maximum load of 100mA and maximum voltage of 24V DC this out put has an open collector NPN transis tor with the emitter connected to GND To use with an external relay a diode must be connected i...

Page 7: ...server into the slot Make sure the bus connector is securely connected to the I O terminal block connector at the back of the rack When repeating the installation procedure for each individual blade video server simply disconnect the blade video server from the rack i e do not disconnect the power cable Secure the video server to the rack using the screws on the front panel The rack accommodates u...

Page 8: ...SPR 22 1997 Class B ICES 003 Metrics Rack Height 5 2 13 2 cm Width 19 0 48 2 cm Length 11 8 30 0 cm Weight 7 3 lb 3 3 kg Video Server Height 1 2 3 1 cm Width 5 1 12 9 cm Length 10 0 25 5 cm Weight 0 5 lb 0 23 kg Power Input Power 100 240 VAC 50 60 Hz 1 6A Operating Conditions Temp 40o to 125oF 5o to 50oC Humidity 20 80 RHG Additional Technical Details For additional technical details see the Techn...

Reviews: