Failure information
TROUBLES, CAUSES, REMEDIES
67
The purpose of the following information is to identify and correct possible faults and
malfunctions that may occur when using the machine.
The various irregularities that may occur were divided into tables, according to the ref-
erence operator unit. It is advisable to examine all tables to know the possible irregu-
larities in a more thorough way.
In case of irregularities that are not specified in the table, the operator can signal them
to the manufacturer in order to actively contribute in developing new solutions, as well
as construction and technical improvements.
Some faults can be solved by the operator; others need a specific technical compe-
tence or particular skills, and must be carried out only by qualified personnel with well-
known experience and acquired within the specific sector of intervention.
In case of need, call the After-Sales Service of the manufacturer, of the local dealer or
an authorised workshop.
Table 1:
Product defects
Trouble
Cause
Cure
Reference
Light bale.
The windrow was not
prepared correctly.
Correct the preparation of
the windrow.
see "How to prepare the
product windrow" in
booklet 2
The speed of the forward
movement is too high
Decrease the speed of the
forward movement.
The PTO rotation rate is
too low.
Increase the PTO rate.
The path of the forward
movement is not correct.
Modify the path of the
tractor.
see "Instructions about
product pick-up" in
booklet 2
The density pressure of
the bale is insufficient.
Increase the set pressure.
see "How to adjust the
solenoid valve for bale
density " in booklet 2
Presence of air inside the
hydraulic circuit for bale
density.
Bleed the air from the
circuit.
Too heavy bale.
The windrow was not
prepared correctly.
Correct the preparation of
the windrow.
see "How to prepare the
product windrow" in
booklet 2
The forward movement
speed is too low.
Increase the speed of the
forward movement.
Bale density pressure is
too high.
Reduce the set pressure.
see "How to adjust the
solenoid valve for bale
density " in booklet 2
Product whose humidity
percentage is too high.
Reduce the humidity
percentage.
Conical bale.
The forward movement
path is not correct:
excessive feeding on one
side.
Modify the path of the
tractor.
see "Instructions about
product pick-up" in
booklet 2
Summary of Contents for RV 4116
Page 2: ......
Page 44: ...IDM 21720307900 pdf General information about the machine 483 004 0 fm IDM English 38 Part 2...
Page 131: ...483 004 0 IDM 125 English Part 8 Attachments...
Page 133: ...IDM 48300401100 pdf 483 004 0 IDM 127 Attachments English Part 8 ESD A01...
Page 137: ...483 004 0 IDM 131 Attachments English Part 8 ESD A05 CAN CABLE 1 IDM 48300101800 pdf...
Page 151: ...483 004 0 IDM 145 Attachments English Part 8 IDM 48300401700 pdf HSD A01...
Page 153: ...483 004 0 IDM 147 Attachments English Part 8 IDM 48300401800 pdf HSD A02...
Page 155: ...483 004 0 IDM 149 Attachments English Part 8...
Page 162: ......
Page 164: ......
Page 168: ...483 011 0IX fm IDM English 2...
Page 192: ......