Electronic control system
E12
Bale density too high
The bale pressure is higher than
the maximum allowed value.
Decrease the forward speed.
The bale density potentiometers
are not regulated properly.
Contact the Technical
Assistance Centre that is
authorised by the manufacturer
E14
Electric power of "twine/net
insertion arm motor" too low
Supply voltage too weak (lower
than 9 V)
Turn off the equipment
Check the correct operation of
the battery and the electric
wiring integrity
E15
Power voltage "PWR OUT" too
low
Supply voltage too weak (lower
than 9 V)
Contact the Technical
Assistance Centre that is
authorised by the manufacturer
E16
Power voltage "5V OUT" too low
Supply voltage too weak (lower
than 4,5 V)
Contact the Technical
Assistance Centre that is
authorised by the manufacturer
E17
Overheating or overload of
electronic card
The temperature of the
electronic card is higher than
70°C
Cool down electronic card
If the problem persists, refer to
the assistance centre authorised
by the manufacturer.
E18
Reset of the default values
The default values of the system
have been reset.
Contact the Technical
Assistance Centre that is
authorised by the manufacturer
Table 1:
Operation failures
n°
Alarm description
Cause
Cure
Summary of Contents for RV 4116
Page 2: ......
Page 44: ...IDM 21720307900 pdf General information about the machine 483 004 0 fm IDM English 38 Part 2...
Page 131: ...483 004 0 IDM 125 English Part 8 Attachments...
Page 133: ...IDM 48300401100 pdf 483 004 0 IDM 127 Attachments English Part 8 ESD A01...
Page 137: ...483 004 0 IDM 131 Attachments English Part 8 ESD A05 CAN CABLE 1 IDM 48300101800 pdf...
Page 151: ...483 004 0 IDM 145 Attachments English Part 8 IDM 48300401700 pdf HSD A01...
Page 153: ...483 004 0 IDM 147 Attachments English Part 8 IDM 48300401800 pdf HSD A02...
Page 155: ...483 004 0 IDM 149 Attachments English Part 8...
Page 162: ......
Page 164: ......
Page 168: ...483 011 0IX fm IDM English 2...
Page 192: ......