34 - 23/May/97
FIG. 1.12 - Motor Phases Wiring (only one axis shown)
Motor
DBM 04
J9/J10/J11
U
V
grounding of shield
via connector clamp
W
V
W
U
grounding of shield
via connector clamp
(or RF connection to
the ground screw in
case of terminal board)
ground
ground
FIG. 1.13A DBM03 Module. J9 Connector. Motor Power (wiring side)
The configuration of this connector depends on the different combinations of sizes .
Notes: M1 always corresponds to the more powerful axis. M3 must not be connected in 2 axis configuration.