25 - 23/May/97
Tab. 1.9 - DBM Module J3 Connector (when EBM Expansion is not present)
Limit Switches Connection (see Fig. 1.9)
The J3 connector allows, when the Expansion is not present, the availability of CW/CCW
limit switches for each axis. With the input enabled (to 0V), the rotation is disabled in one
direction and enabled in the other direction.
When the Expansion is present, the J3 connector is used for signal connection to the
Expansion module.
Pos Name
1
0V common
2
CW limit switch, axis 1
3
N.C.
4
N.C.
5
CCW limit switch, axis 1
6
CW limit switch, axis 2
7
N.C.
8
N.C.
9
N.C.
10
N.C.
11
N.C.
12
CCW limit switch, axis 2
13
CW limit switch, axis 3
14
CCW limit switch, axis 3
15
0V common
Note: CW means clockwise rotation when viewed from shaft end, with default DI command.