124 - 23/May/97
L1
6.2.2 FILTER SIZING
The filter/drive coupling in the table is a standard coupling. In normal applications the filter
can be choosen according to the table. The filters can be undersized according to the size of
the modules in case of multi-axis application. This should be done not only because, as a
matter of fact, undersizing the filter means less money, but because the undersized filter
provides better performance to EMC.
Example:
- DBM PS 03 + DBM 03 5-5-5 + DBM 03 5-5-5 and contemporaneity factor of 0.8.
For this application it is not necessary to use the 100A filter of the table.
The reference current is Iin = 6
∗
5
∗
0.8 = 24 A
A 30A filter (FN 258-30/7) can safely be used.
6.2.3. FILTER DIMENSIONS
Vickers
code
Trade-mark
Dimensions
[mm]
Weight
L1
L2
L3
L4
L5
L6
l7
[kg]
AT6008
Schaffner
FN 250-6/07*
85
75
54
0
65
30
300
0.24
AT6009
Schaffner
FN 258-7/07
255
240
50
25
225
±
0.8 126
±
0.8
300
1.1
AT6010
Schaffner
FN 258-16/07
305
290
55
30
275
±
0.8 142
±
0.8
300
1.7
AT6011
Schaffner
FN 258-30/07
335
320
60
35
305
150
400
1.8
AT6012
Schaffner
FN 258-42/07
329
314
70
45
300
185
500
2.8
AT6013
Schaffner
FN 258-55/07
329
314
80
55
300
185
500
3.1
AT6014
Schaffner
FN 258-75/34
329
314
80
55
300
220
terminal
block
4
AT6015
Schaffner
FN 258-100/35
379
±
1.5
364
90
±
0.8
65
350
±
1.2 220
±
1.5
terminal
block
5.5
*= the FN250-6/07 filter has wiring leads (length=300mm) at both sides.
TOP VIEW
SIDE VIEW
L2
L4
L3
L6
L5
L7
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com