8 - 23/May/97
1.6 CE-Marking
Starting from Jan/97, DBM03 drives have CE-marking according to Low Voltage Directive.
Starting from Apr/97 the CE-marking refers also to EMC Directive (see Section 6).
A Declaration of Conformity is available.
The Low Voltage Directive applies to all electrical equipment designed to use with a voltage
rating of between 50 Vac and 1000 Vac and between 75 Vdc and 1500 Vdc.
The CE-marking states that the electrical equipment has been constructed in accordance
with good engineering practice in safety matters in force in the European Community and it
does not endanger the safety of persons, domestic animals or property when properly
installed and maintained and used in applications for which it was made.
Vickers drives meet the following standard related to Low Voltage Directive:
CEI EN 60204-1 (1993)
par. 6.2.3, 20.3, 20.4
1.7 System Wiring
All of the analog and digital signal connectors, auxiliary power supplies and I/O interfaces are
front-connected to the unit.
Connectors for auxiliary power supply are made via Molex type connectors. Motor power are
connected via a Harting type connector, while I/O connectors use a Weildmuller type
connector.
All other connectors are made via D-type connectors.
All signals are positive logic:
active =
+15V
not active = 0V (or not connected)
1.8 DBM Configurations
Three configurations are possible for the module:
DBM-3A:
3-axis module (see Fig. 1.3)
DBM-2A:
2-axis module (see Fig. 1.4)
DBM-2E:
2-axis module with expansion (see Fig. 1.5)
DBM-L3A:
3-axis 180 mm module (see Fig. 1.6)
DBM-L2A:
2-axis 180 mm module (see Fig.1.7)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com