11 - 23/May/97
Tab. 1.1 - DBM-PS Power Supply (See Fig. 1.2)
Pos.
Name
1
R
"L1" phase, three-phase input voltage 230Vac
2
S
"L2" phase, three-phase input voltage 230Vac
3
T
"L3" phase, three-phase input voltage 230Vac
4
GND
Ground
5
RR
Recovery resistor
6
RR
Recovery resistor
7
AUX
Auxiliary power supply 230Vac (110Vac as option)
8
AUX
Auxiliary power supply 230Vac (110Vac as option)
9
Yellow LED
PWR-BUS
BUS BAR voltage > 40Vdc
10
Red LED
DBR FAULT
Recovery unit fault
11
N.C.
12
Red LED
OVER
TEMP
Module overtemperature via PTC (threshold 80
°
C)
13
Green LED
AUX
POWER
Auxiliary power supply OK
14
J2
RS485 output port to drives and power control fault
15
J10
RS485 input port
16
J1
Auxiliary power supply flat connector
17
GND
Ground
18
L-
BUS BAR -HV 300Vdc
19
L+
BUS BAR +HV 300Vdc
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com