FCC ID: K6620285X20
IC ID: 511B-20285X20
VX-3R Operating Manual
BEAM: The BUSY/TX indicator glows continuously in white.
BP+BEM: Loud “Alarm” sounds and the BUSY/TX indicator glows continuously in white.
CW: The BUSY/TX indicator flashes according to the programmed Emergency message (Morse
Code)* at a rate of five words per minute.
BP+CW: Sounds tones via the speaker, and flashes the BUSY/TX indicator, according to the
programmed Emergency message (Morse Code)* at a rate of five words per minute.
CWT: Transmits the programmed Emergency message (Morse Code)* and flashes the
BUSY/TX indicator, according to the programmed Emergency message (Morse Code)*
on the air beginning one minute after activation of the Emergency function.
*The internationally-recognized Morse Code “S.O.S” message (•••– – –•••) is programmed at the
factory for the Emergency message.
Here’s how to program the Emergency Message:
1. Set this Set Mode Item to “CW” or “BP+CW.”
2. Press the [V/M] key to display any previously-stored emergency message.
3. Press the [HM/RV] key to clear any previous emergency message, if desired.
4. Rotate the DIAL knob to select the first letter/number of the message, then press the [V/M]
key momentarily to save the first letter/number and move on to the next character.
5. Repeat the previous step as necessary to complete the message (up to 16 characters).
6. If you make a mistake, press the [BAND] key to back-space the cursor; now re-enter the
correct letter/number.
7. Press the [HM/RV] key to delete all data after the cursor that may have been previously
stored erroneously.
8. When you have entered the message, press the [TXPO] key momentarily to confirm the
message, then press the PTT switch to save the settings and exit to normal operation.
Set Mode Item 33 [EXT.MNU]
Function: Enables/Disables the extended Set Mode Menu.
Available Values: ON/OFF
Default: OFF
Set Mode Item 34 [FW KEY]
Function: Set the duration that a secondary function of the [F/W] key (press and holding the [F/W]
key) is held determines the function they activate.
Available Values: FW0.3S/FW0.5S/FW0.7S/ FW1.0S/FW1.5S
Default: FW0.5S
Set Mode Item 35 [HLF.DEV]*
Function: Reducing the Deviation level by 50 %.
Available Values: ON/OFF
Vertex Standard Co., Ltd.
74