FCC ID: K6620285X20
IC ID: 511B-20285X20
VX-3R Operating Manual
1. Set the VX-3R to the VFO mode.
2. Press and hold in the [TXPO] key for one second to enter the Set mode.
3. Rotate the DIAL knob to select Set Mode Item 91: VFO.SKP.
Note: Do not forget to pull the DIAL knob to rotate the DIAL knob.
4. Press the [TXPO] key momentarily to enable adjustment of this Item.
5. Rotate the DIAL knob to choose a band number (see chart below) you wish to skip (omit) form the
band selection loop.
6. Press the [V/M] key, then rotate the DIAL knob to select “OFF” (to skip (omit) from the band selection
loop).
Note: The band presently in use cannot select “OFF”.
7. Press the [V/M] key again.
8. Repeat steps 4 through 6 above to select as many bands as you like.
9. When you have made your selection, press the PTT switch to save the new setting and return to
normal operation.
To re-institute a band into the band selection loop, repeat the above procedure, rotating the DIAL knob to
select “ON” in step 5.
R.F. Say: If you wish to skip (omit) the AM or FM Broadband, enter the Broadcast Reception mode by
pressing the [RADIO] key momentarily at first, then perform the above procedure.
Band Number Chart
B
AND
N
UMBER
B
AND
F
REQUENCY
R
ANGE
1
SW Band
1.8 - 30 MHz
2
50 MHz Ham Band
30 - 59 MHz
3
Air Band
108 - 137 MHz
4
144 MHz Ham Band
137 - 174 MHz
5
VHF-TV Band
174 - 222 MHz
6
Information Band 1
222 - 420 MHz
7
430 MHz Ham Band
420 - 470 MHz
8
UHF-TV Band
470 - 800 MHz
9
Information Band 2
803 - 999 MHz
A
AM Broadcast Band
510 – 1790 kHz
F
FM Broadcast Band
76 - 107.9 MHz
Reset Procedures
In some instances of erratic or unpredictable operation, the cause may be corruption of data in the
Vertex Standard Co., Ltd.
67