SD500 Spindle Servo Drive Manual
64
Tens-bit: Power-down storage
0: power-down frequency storage off
1: power-down frequency storage on
Hundreds-bit: Restrictions
0: adjustable during stop
1: adjustable only during running, stored during stop
2: adjustable during running, cleared during stop
F11.05
(0x0B05)
Up / down for quick
change of parameter
code
V/F SVC FVC PMVF PMSVC PMFVC
Ones- and tens-bit: set 00~99 to yy in the function code
Fxx.yy.
Hundreds- and thousands-bit: set 00~15 to xx in the
function code Fxx.yy.
0109
(0000~1563)
RUN
Table 4-38
Group F11.1x: Cycle monitoring on the status interface
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F11.11
(0x0B0B)
Cyclic display
parameter 1 on the 1
st
cable
V/F SVC FVC PMVF PMSVC PMFVC
Ones- and tens-bit: set 00~63to yy in the function code
Cxx.yy.
百位
Thousands-bit: :
监视参数号
Cxx.yy
中
xx
设定
00~07
0000
(0000~0763)
RUN
F11.12
(0x0B0C)
Cyclic
display
parameter 2 on the 1
st
cable
V/F SVC FVC PMVF PMSVC PMFVC
Ones- and tens-bit: set 00~63to yy in the function code
Cxx.yy.
0001
(0000~0763)
RUN
F11.13
(0x0B0D)
Cyclic
display
parameter 3 on the 1
st
cable
V/F SVC FVC PMVF PMSVC PMFVC
Ones- and tens-bit: set 00~63to yy in the function code
Cxx.yy.
0002
(0000~0763)
RUN
F11.14
(0x0B0E)
Cyclic
display
parameter 4 on the 1
st
cable
V/F SVC FVC PMVF PMSVC PMFVC
Ones- and tens-bit: set 00~63to yy in the function code
Cxx.yy.
0011
(0000~0763)
RUN
Table 4-39
Group F11.2x: Monitoring parameter control
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F11.20
(0x0B14)
Keyboard
display
settings
V/F SVC FVC PMVF PMSVC PMFVC
Ones-bit: Output frequency display selection
0002
(0000~111f)
RUN