SD500 Spindle Servo Drive Manual
61
1:
overload detection;
2:
overload detection at constant speed only;
3:
underload detection
4: underload detection at constant speed only;
5: overload detection (position control valid)
6: underload detection (position control valid)
LED thousands-bit: Warning selection
0: report the warning and continue running
1: protections on and free stop
F10.33
(0x0A21)
Load warning
detection level 1
V/F SVC FVC PMVF PMSVC PMFVC
Set the detection value 1 of load warning.
For VF control, it is 100% of the rated motor current.
For vector control, it is 100% the rated output torque of the
motor.
130.0%
(0~200.0%)
STOP
F10.34
(0x0A22)
Load warning
detection time 1
V/F SVC FVC PMVF PMSVC PMFVC
Set the duration of the detection of load warning 1, the load
is greater than the load warning detection level after the
duration of the time, report the load detection warning 1.
5.0s
(0~60.0)
STOP
F10.35
(0x0A23)
Load warning
detection level 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the detection value 2 of load warning.
For VF control, it is 100% of the rated motor current.
For vector control, it is 100% the rated output torque of the
motor.
130.0%
(0~200.0%)
STOP
F10.36
(0x0A24)
Load warning
detection time 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the duration of the detection of load warning 2, the load
is greater than the load warning detection level after the
duration of the time, report the load detection warning 2.
5.0s
(0~60.0)
STOP
Table 4-35
Group F10.4x: Stall protection
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F10.40
(0x0A28)
Excessive
speed
deviation protection
V/F SVC FVC PMVF PMSVC PMFVC
Set the selection of early warning detection method and
00
(00~12)
STOP