SD500 Spindle Servo Drive Manual
46
F05.72
(0x0548)
Curve 2 inflection
point 1 input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set curve 2 inflection point 1 input voltage.
30.0%
(0.0~100.0%)
RUN
F05.73
(0x0549)
Percent of curve 2
inflection point 1
input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set percent of curve 2 inflection point 1 input voltage.
30.00%
(0.00~100.00%)
RUN
F05.74
(0x054A)
Curve 2 inflection
point 2 input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set curve 2 inflection point 2 input voltage.
60.0%
(0.0~100.0%)
RUN
F05.75
(0x054B)
Percent of curve 2
inflection point 2
input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set percent of curve 2 inflection point 2 input voltage.
70.00%
(0.0~100.0%)
RUN
F05.76
(0x054C)
Curve 2 upper limit
V/F SVC FVC PMVF PMSVC PMFVC
Set curve 2 upper limit.
100.00%
(0.0~100.0%)
RUN
F05.77
(0x054D)
Percent of curve 2
upper limit
V/F SVC FVC PMVF PMSVC PMFVC
Set percent of curve 2 upper limit
100.0%
(0.0~100.0%)
RUN
Table 4-29
Group F05.8x:AI as digital input terminal
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F05.80
(0x0550)
AI as digital input
terminal
characteristics
selection
V/F SVC FVC PMVF PMSVC PMFVC
0: Valid at low level
1: Valid at high level
Ones-bit:AI1
Tens-bit:AI2
0000
(0000~1111)
RUN
F05.81
(0x0551)
AI terminal function
selection (as X
terminal)
V/F SVC FVC PMVF PMSVC PMFVC
See X terminal functions.
0
(0~63)
STOP
F05.82
(0x0552)
AI high level setting
V/F SVC FVC PMVF PMSVC PMFVC
An input higher than the set value here is a high-level input.
70.00%
(0.0~100.0%)
RUN
F05.83
(0x0553)
AI low level setting
V/F SVC FVC PMVF PMSVC PMFVC
An input lower than the set value here is a low-level input.
30.00%
(0.0~100.0%)
RUN
Table 4-30
4.8 Group F06: Output Terminal
Group F06.0x:AO analog output