SD500 Spindle Servo Drive Manual
85
keyboard numbers
to 0.
frequency set via
numbers)
F01.22
(0x0116)
Acceleration time 1
V/F SVC FVC PMVF PMSVC PMFVC
The time it takes to accelerate the output frequency from
0.00Hz to the reference frequency.
1~65000s(F01.21 = 0)
0.1~6500.0s(F01.21 = 1)
0.01~650.00s(F01.21 = 2)
Set by models
(0.01~650.00s)
RUN
F01.23
(0x0117)
Deceleration time1
V/F SVC FVC PMVF PMSVC PMFVC
The time it takes to accelerate the output frequency from
0.00Hz to the reference frequency.
Set by models
(0.01~650.00s)
RUN
F03.02
(0x0302)
ASR (speed loop)
proportional gain1
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR (speed loop) proportional gain 1.
20.00
(0.01~100.00)
RUN
F03.03
(0x0303)
ASR (speed loop)
integral time 1
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR (speed loop) integral time 1.
0.100s
(0.000~6.000s)
RUN
F03.04
(0x0304)
ASR filter time1
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR filter time 1.
0.0ms
(0.0~100.0ms)
RUN
F03.05
(0x0305)
ASR switching
frequency1
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR switching frequency 1.
10.00Hz
(0.00~
Max.
frequency)
RUN
F03.06
(0x0306)
ASR (speed loop)
proportional gain2
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR (speed loop) proportional gain 2.
20.00
(0.01~100.00)
RUN
F03.07
(0x0307)
ASR (speed loop)
integral time 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR (speed loop) integral time 2.
0.050s
(0.000~6.000s)
RUN
F03.08
(0x0308)
ASR filter time 2
V/F SVC FVC PMVF PMSVC PMFVC
Set ASR filter time 2.
0.0ms
(0.0~100.0ms)
RUN
F03.09
(0x0309)
ASR switching
frequency 2
V/F SVC FVC PMVF PMSVC PMFVC
Set ASR switching frequency 2.
5.00Hz
(0.00~
Max.
frequency)
RUN
F15.33
(0x0F21)
ADRC observer gain
β2
V/F SVC FVC PMVF PMSVC PMFVC
For improving system response and rigidity.
100
(0~200)
RUN
F15.34
(0x0F22)
ADRC input factor b
V/F SVC FVC PMVF PMSVC PMFVC
For improving system response and rigidity.
32
(1~200)
RUN