SD500 Spindle Servo Drive Manual
28
F01.21
(0x0115)
Acceleration time unit
V/F SVC FVC PMVF PMSVC PMFVC
Set unit of acceleration time.
0:1S 1:0.1S 2:0.01S
2
(0~2)
STOP
F01.22
(0x0116)
Acceleration time 1
V/F SVC FVC PMVF PMSVC PMFVC
The time it takes to accelerate the output frequency from
0.00Hz to the time reference frequency.
1~65000s (F01.21 = 0)
0.1~6500.0s (F01.21 = 1)
0.01~650.00s (F01.21 = 2)
Set by
models(0.01~650.00s)
RUN
F01.23
(0x0117)
Deceleration time1
V/F SVC FVC PMVF PMSVC PMFVC
The time it takes for the output frequency to decelerate from
the time reference frequency to 0.00Hz.
Set by
models(0.01~650.00s)
RUN
F01.30
(0x011E)
S-curve
acceleration/deceleration
selection
V/F SVC FVC PMVF PMSVC PMFVC
Whether S curve acceleration / deceleration setting is valid
0: Invalid; 1: Valid
0
(0~1)
STOP
F01.31
(0x011F)
Accelerate time to start
S-curve
V/F SVC FVC PMVF PMSVC PMFVC
Set the acceleration time to start S-curve.
0.20s
(0.00~10.00)
STOP
F01.32
(0x0120)
Accelerate time to end
S-curve
V/F SVC FVC PMVF PMSVC PMFVC
Set the acceleration time to end S-curve.
0.20s
(0.00~10.00)
STOP
F01.33
(0x0121)
Decelerate time to start
S-curve
V/F SVC FVC PMVF PMSVC PMFVC
Set the deceleration time to start S-curve.
0.20s
(0.00~10.00)
STOP
F01.34
(0x0122)
Decelerate time to end
S-curve
V/F SVC FVC PMVF PMSVC PMFVC
Set the deceleration time to end S-curve.
0.20s
(0.00~10.00)
STOP
F01.35
(0x0123)
Switching frequency
between acceleration
time 1 and time 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the switching frequency of acceleration time 1 and
acceleration time 2.
0.00Hz
(0.00~ Max.
frequency set via
numbers)
RUN
Table 4-7
Group F01.4x: PWM control
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F01.40
(0x0128)
Carrier frequency
V/F SVC FVC PMVF PMSVC PMFVC
Used to set the switching frequency of the spindle drive IGBT.
Set by models
(1.0~16.0kHz)
RUN