Group F06.2x-F06.3x: Digital, relay outputs
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F06.20
(0x0614)
Output terminal
polarity selection
V/F SVC FVC PMVF PMSVC PMFVC
0:Positive
;
1: Negative
Ones-bit: Y terminal
Tens-bit: Relay output terminal 1
0000
(0000~1111)
RUN
F06.21
(0x0615)
Output terminal Y1
V/F SVC FVC PMVF PMSVC PMFVC
See terminal Y functions.
42
(0~43)
RUN
F06.22
(0x0616)
Relay 1 output
(TA-TB-TC)
V/F SVC FVC PMVF PMSVC PMFVC
See terminal Y functions.
41
(0~43)
RUN
F06.23
(0x0617)
Output terminal Y2
V/F SVC FVC PMVF PMSVC PMFVC
See terminal Y functions.
8
(0~43)
RUN
F06.24
(0x0618)
Relay 2 output
(TA-TB-TC)
V/F SVC FVC PMVF PMSVC PMFVC
See terminal Y functions.
4
(0~43)
RUN
F06.25
(0x0619)
Y1 output ON delay
time
V/F SVC FVC PMVF PMSVC PMFVC
Set the Y1 output ON delay time.
0.010s
(0.000~60.000s)
RUN
F06.26
(0x061A)
Relay 1 output ON
delay time
V/F SVC FVC PMVF PMSVC PMFVC
Set the relay 1 output ON delay time.
0.010s
(0.000~60.000s)
RUN
F06.27
(0x061B)
Y2 output ON delay
time
V/F SVC FVC PMVF PMSVC PMFVC
Set the Y2 output ON delay time.
0.010s
(0.000~60.000s)
RUN
F06.28
(0x061C)
Relay 2 output ON
delay time
V/F SVC FVC PMVF PMSVC PMFVC
Set the relay 2 output ON delay time.
0.010s
(0.000~60.000s)
RUN
F06.29
(0x061D)
Y1 output OFF delay
time
V/F SVC FVC PMVF PMSVC PMFVC
Set the Y2 output OFF delay time.
0.010s
(0.000~60.000s)
RUN
F06.30
(0x061E)
Relay 1 output OFF
delay time
V/F SVC FVC PMVF PMSVC PMFVC
Set the relay 1 output OFF delay time.
0.010s
(0.000~60.000s)
RUN
F06.31
(0x061F)
Y2 output OFF delay
time
V/F SVC FVC PMVF PMSVC PMFVC
Set the Y2 output OFF delay time.
0.010s
(0.000~60.000s)
RUN
F06.32
(0x0620)
Relay 2 output OFF
delay time
V/F SVC FVC PMVF PMSVC PMFVC
Set the relay 2 output OFF delay time.
0.010s
(0.000~60.000s)
RUN
Table 4-32