SD500 Spindle Servo Drive Manual
60
F10.25
(0x0A19)
Spindle
drive
overheating
oH1
warning
detection
level
V/F SVC FVC PMVF PMSVC PMFVC
Set the temperature value for spindle drive overheating
warning, report the overheating warning when it’s greater
than the value.
80.0℃
(0~100.0)
RUN
Table 4-34
Group F10.3x: Load protection
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F10.30
(0x0A1E)
Motor
overload
protection
curve
factor
V/F SVC FVC PMVF PMSVC PMFVC
Set the factor of overload protection for the load motor,
increasing this value will increase the overload capacity of
the motor.
100.0%
(0~250.0%)
STOP
F10.31
(0x0A1F)
Selection of spindle
drive
overload
characteristics at low
speeds
V/F SVC FVC PMVF PMSVC PMFVC
Set whether the spindle drive overload protection function is
effective at low speed (below 5Hz)
0: invalid
1: valid
0
(0~1)
STOP
F10.32
(0x0A20)
Load warning
detection setting
V/F SVC FVC PMVF PMSVC PMFVC
Set the spindle drive load warning detection method and the
according warning method
LED ones-bit: Detection selection (protection 1)
0:
no detection;
1:
overload detection;
2:
overload detection at constant speed only;
3:
underload detection
4: underload detection at constant speed only;
5: overload detection (position control valid)
6: underload detection (position control valid)
LED tens-bit: Warning selection
0: report the warning and continue running
1: protections on and free stop
LED hundreds-bit: detection selection (protection 2)
0:
no detection;
0000
(0000~1414)
STOP