SD500 Spindle Servo Drive Manual
82
Chapter 5 Spindle Function Application Guidance
5.1 Motor Self-Learning
Motor self-learning is required before commissioning.
Please refer to the control circuit wiring diagram for wiring definitions, and
parameters are as follows.
Code
(Address)
Designation
Content
Factory value
(setting range)
Adjustable
properties
F01.00
(0x0100)
Motor 1 control
method
V/F SVC FVC PMVF PMSVC PMFVC
Control mode of motor
0:AM-VF; asynchronous motor V/F control
1:AM-SVC; asynchronous motor open-loop vector control
2:AM-FVC; asynchronous motor closed-loop vector control
10:PM-VF; synchronous motor V/F control
11:PM-SVC; synchronous motor open-loop vector control
12:PM-FVC; synchronous motor closed-loop vector control
2
(0 ~12)
STOP
F02.01
(0x0201)
Motor poles No.
V/F SVC FVC PMVF PMSVC PMFVC
Set the number of motor poles.
4
(2~98)
STOP
F02.02
(0x0202)
Motor rated power
V/F SVC FVC PMVF PMSVC PMFVC
Set the rated power of the motor.
Set by models
(0.1~1000.0kW)
STOP
F02.03
(0x0203)
Motor rated
frequency
V/F SVC FVC PMVF PMSVC PMFVC
Set the rated frequency of the motor.
Set by models
(0.01~
Max.
frequency)
STOP
F02.04
(0x0204)
Motor rated speed
V/F SVC FVC PMVF PMSVC PMFVC
Set the rated speed of the motor.
Set by models
(0~65000rpm)
STOP
F02.05
(0x0205)
Motor rated voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set the rated voltage of the motor.
Set by models
(0~1500V)
STOP
F02.06
(0x0206)
Motor rated current
V/F SVC FVC PMVF PMSVC PMFVC
Set the rated current of the motor.
Set by models
(0.1~3000.0A)
STOP
F02.30
(0x021E)
Speed feedback
encoder type
V/F SVC FVC PMVF PMSVC PMFVC
0: normal ABZ encoder
4: sine-cosine encoder
0
(0~2)
STOP
F02.33
(0x0221)
ABZ encoder cable
No.
V/F SVC FVC PMVF PMSVC PMFVC
Sets the number of ABZ encoder cables.
2500
(1~10000)
STOP
F02.40
Encoder installation
V/F SVC FVC PMVF PMSVC PMFVC
0
STOP