MUS0920201
07/10/2014 60
MELTON, S.L.U. - POLIGONO INDUSTRIAL AGUSTINOS CALLE G-34,31160 ORCOYEN, NAVARRA
TEL: 00 34 948 321580 Fax: 00 34 948 326584 e-mail: [email protected]
6.3.3. BLEEDING:
The bleed process is done to sweep away small crystallisations that may be
produced in the filter and if you wish to depressurise the system.
Before purging the filter, put on goggles, gloves and a long-
sleeve shirt to prevent possible burns caused by hot adhesive
splashing.
Bleeding the filter is not recommended when running PUR
adhesives
1. To purge the filter, the applicator must be at the operating temperature.
2. Stopped pump.
3. Place a container below the machine to collect the adhesive in the manifold.
4. Open the bleed valve with a key.
5. Close the bleed valve with a wrench.
6. Return the pressure to the appropriate operating pressure.
7. When the machine is at the programmed temperature and there are no alarms
activated, the pump permission will turn on.
8. The application can start.